Briefing
Highly sensitive electrochemical detection of circulating tumor DNA in human blood based on urchin-like gold nanocrystal-multiple graphene aerogel and target DNA-induced recycling double amplification strategy
Yuanfeng P, Ruiyi L, Xiulan S, Guangli W, Zaijun L
Authors' conclusion: Electrochemical response increases with ctDNA concentration from 0.1 to 1 × 106 fM with detection limit of 0.033 fM. The biosensor provides ultrahigh sensitivity, specificity and stability and was successfully applied in detection of ctDNA in human blood.
- Design: Original research. PubMed index, not yet editor-reviewed
Anal Chim Acta (opens in a new tab)PubMed 32493585 (opens in a new tab)DOI 10.1016/j.aca.2020.04.077 (opens in a new tab)